For infrastructure managers, railway undertakings, signalling suppliers and maintenance organisations, protecting signalling systems requires more than conventional network security. Security measures must account for railway operating conditions, legacy equipment, system availability, safety engineering and the consequences of unauthorised access or manipulation. This article examines the architecture, attack surfaces, threat scenarios and cybersecurity controls relevant to modern railway signalling and train control systems.
1. What Is Railway Signalling Cybersecurity?
Railway signalling cybersecurity refers to the technical and organisational measures used to protect signalling and train control systems against malicious activity, unauthorised access, data manipulation, disruption and other security threats.
These systems perform functions that directly support train movement and operational control. Depending on the railway architecture, they may include:
- Interlocking systems and signalling control equipment.
- Track vacancy detection and train detection systems.
- European Train Control System (ETCS) trackside and onboard equipment.
- Radio Block Centres (RBCs).
- Eurobalises and Lineside Electronic Units (LEUs).
- Automatic Train Protection (ATP) systems.
- Communications-Based Train Control (CBTC) systems.
- Engineering workstations and configuration tools.
- Signalling communication networks and maintenance interfaces.
The objective is to preserve the integrity, availability and confidentiality of the systems and information involved, while ensuring that cybersecurity measures do not compromise railway safety or operational requirements.
2. Understanding Railway Signalling Architecture
Before assessing cyber risks, it is important to understand how signalling components interact. Railway signalling is not a single computer or network. It is a combination of distributed equipment, control functions, communication links and operational interfaces.
2.1 Interlocking Systems
Interlocking is a core signalling function that establishes and protects train routes. It controls signals and points, processes information from train detection equipment and prevents incompatible routes from being established simultaneously.
Modern interlocking systems may use computer-based architectures, distributed input/output equipment, engineering workstations and communication networks. Depending on the design, interfaces may connect interlocking to traffic control systems, level crossings, ETCS trackside equipment and maintenance platforms.
Cybersecurity considerations include:
- Protection of engineering and configuration interfaces.
- Control of privileged accounts and maintenance access.
- Integrity of software, configuration data and updates.
- Protection of communication links with external systems.
- Detection of unauthorised changes and unusual access.
- Secure management of supplier and maintenance connections.
Interlocking is not itself an ERTMS subsystem, but it plays an essential role in many ERTMS architectures. Its interfaces with ETCS trackside equipment and other signalling components must therefore be included in the cybersecurity assessment.
2.2 Track Vacancy Detection
Train detection systems provide information about whether a section of track is occupied. Common technologies include track circuits and axle counters.
These systems provide inputs to signalling and interlocking functions. Their cybersecurity assessment should consider device configuration, communication interfaces, maintenance access, software or firmware integrity where applicable, and the availability of associated equipment.
Security controls must be designed around the actual detection technology. A track circuit and an axle counter do not necessarily have the same architecture, interfaces or maintenance requirements.
2.3 ETCS Trackside Equipment
The European Train Control System (ETCS) provides automatic train protection through continuous or intermittent supervision of train movements, depending on the operational level and configuration.
Trackside ETCS equipment may include:
- Eurobalises.
- Lineside Electronic Units (LEUs).
- Radio Block Centres (RBCs).
- Radio Infill Units (RIUs), where deployed.
- Interfaces with interlocking and other signalling equipment.
- Trackside engineering and maintenance systems.
These components exchange information that contributes to the train’s understanding of its position, route conditions and movement authority.
2.4 Onboard Train Control Equipment
The onboard ETCS subsystem receives and processes information from trackside equipment and supervises train movement. Depending on the configuration, it may include:
- European Vital Computer (EVC).
- Balise Transmission Module (BTM).
- Driver Machine Interface (DMI).
- Odometry and train positioning interfaces.
- Train interfaces and braking system connections.
- Onboard communication equipment.
Cybersecurity assessment must consider the onboard environment as well as the trackside infrastructure. Trains may connect to depot networks, diagnostic platforms, maintenance laptops and remote support services, creating additional interfaces that require protection.
3. ERTMS and ETCS: Understanding the Scope
The European Rail Traffic Management System (ERTMS) is a European framework designed to improve railway interoperability. It includes ETCS, railway mobile radio and associated operational rules. Automatic Train Operation (ATO) is also used alongside ETCS in relevant configurations, with ETCS providing the train protection function.
It is important not to use ERTMS and ETCS as interchangeable terms:
- ERTMS: The broader European railway traffic management and interoperability framework.
- ETCS: The train control and automatic train protection system.
- GSM-R: The established digital radio system used for railway voice and data communication.
- FRMCS: The future railway mobile communication system intended to succeed GSM-R.
- ATO: Automatic Train Operation, which can work with ETCS as the train protection system.
ERTMS cybersecurity therefore involves multiple technologies and organisational responsibilities. A security assessment should identify the actual systems, interfaces and operational arrangements rather than treating the entire environment as a single component.
4. ETCS Levels and Cybersecurity Considerations
ETCS architecture influences the communication paths, equipment and potential attack surfaces that need to be assessed. The security implications depend on the specific implementation and not only on the ETCS level designation.
4.1 ETCS Level 1
ETCS Level 1 uses intermittent track-to-train transmission, typically through Eurobalises. The onboard equipment reads information when the train passes over the relevant balise. Train movement is supervised onboard.
Cybersecurity considerations include:
- Integrity and configuration of balise telegrams.
- Protection of LEU and interlocking interfaces.
- Secure engineering and maintenance processes.
- Protection of onboard equipment and diagnostic interfaces.
- Control of access to configuration and testing tools.
Eurobalises are passive trackside devices. They do not operate as conventional powered network nodes. Their security assessment must therefore focus on the complete information chain, including the equipment and processes that generate, configure, validate and transmit the telegrams.
4.2 ETCS Level 2
ETCS Level 2 uses radio communication between the train and the trackside system. The Radio Block Centre receives train position information and provides movement authorities and other information required for train operation.
The architecture introduces additional communication and infrastructure dependencies, including:
- Radio Block Centre systems.
- GSM-R or another supported railway radio communication arrangement.
- Interlocking interfaces.
- Trackside communication networks.
- Onboard communication and ETCS equipment.
- RBC-to-RBC communication where applicable.
Cybersecurity assessment should examine authentication, message integrity, availability, network segmentation, system configuration and the security of maintenance interfaces.
4.3 ETCS Level 3 and Evolving Architectures
ETCS Level 3 concepts have involved greater reliance on onboard train integrity information and more advanced train position supervision arrangements. The precise architecture and deployment status depend on the applicable specifications and implementation.
As railway systems evolve towards more connected and digital architectures, risk assessments should consider the additional dependencies introduced by onboard systems, communication networks, software platforms and operational data exchange.
It is not appropriate to assume that all ETCS deployments have identical equipment, communication paths or security characteristics.
5. Main Cybersecurity Attack Surfaces in Railway Signalling
An attack surface is the collection of interfaces, services, components and access paths through which a threat actor may attempt to interact with a system.
In railway signalling environments, relevant attack surfaces may include:
| Attack surface | Potential exposure | Security priority |
|---|---|---|
| Engineering workstations | Configuration tools, privileged accounts and maintenance software | High |
| Interlocking interfaces | Connections to external signalling and operational systems | High |
| RBC infrastructure | Server access, network interfaces and communication dependencies | High |
| Trackside communication networks | Network equipment, management interfaces and external connections | High |
| Onboard equipment | Diagnostic interfaces, software updates and depot connections | High |
| Maintenance access | Supplier accounts, remote sessions and portable engineering devices | High |
| Software and firmware supply chain | Third-party components, updates and development environments | High |
| Physical access points | Equipment rooms, cabinets and local maintenance ports | Context-dependent |
The existence of an interface does not automatically mean that it is vulnerable. Risk depends on its exposure, design, access controls, operational use and the effectiveness of existing safeguards.
6. Threat Scenarios Affecting Railway Signalling
Cybersecurity risk assessment should use realistic scenarios that reflect the architecture and operational environment of the railway system.
6.1 Unauthorised Access to Engineering Workstations
Engineering workstations may provide access to configuration tools, diagnostic functions and maintenance interfaces. Compromised credentials, malicious software or misuse of privileged access could allow an unauthorised user to interact with sensitive signalling environments.
Potential consequences include unauthorised configuration activity, disruption of maintenance processes or compromise of the integrity of engineering information.
6.2 Compromise of Remote Maintenance Access
Signalling equipment may be supported by manufacturers, system integrators or specialist maintenance providers. Remote access can improve maintenance efficiency but also creates an external access path.
Risks include compromised supplier accounts, excessive privileges, unmanaged maintenance devices and connections that remain active longer than necessary.
Remote access should be approved, time-limited, authenticated, monitored and restricted to the required systems and functions.
6.3 Manipulation of Configuration or Software
Unauthorised modification of signalling software, configuration data or firmware may affect system behaviour or availability. The potential consequences depend on the system, the nature of the modification and the safeguards in place.
Protection should include controlled configuration management, integrity verification, secure update procedures, access restrictions and independent validation where required.
6.4 Denial of Service Against Communication Infrastructure
Communication disruption may affect the exchange of information between trackside and onboard systems or reduce the availability of supporting services.
The risk assessment should consider the communication architecture, redundancy, coverage, fallback arrangements and the operational procedures available when communication is degraded or unavailable.
6.5 Supply Chain Compromise
Signalling systems often depend on specialised hardware, software, firmware and maintenance services supplied by multiple organisations.
A compromise affecting a supplier’s development, update or support environment may introduce risks into the railway system. Supplier assurance, secure development practices, software integrity checks and vulnerability management are therefore important elements of signalling cybersecurity.
6.6 Insider Threats and Misuse of Privileges
Employees, contractors and supplier personnel may have legitimate access to sensitive systems. Excessive privileges, shared accounts, inadequate supervision or malicious actions can create significant security risks.
Organisations should use individual accounts, role-based access, separation of duties, privileged access management and appropriate logging.
7. Protecting Interlocking Systems
Interlocking systems require security measures that reflect their safety-related functions and operational requirements.
Important cybersecurity controls include:
- Documented system boundaries and communication interfaces.
- Network separation from non-essential corporate services.
- Strict control of engineering and maintenance access.
- Unique user accounts and strong authentication where supported.
- Controlled software and configuration changes.
- Integrity protection for approved software and configuration baselines.
- Secure backup and restoration procedures.
- Monitoring of administrative activity and relevant system events.
- Supplier security requirements and maintenance procedures.
- Periodic assessment of vulnerabilities and unsupported components.
Security testing must be carefully planned. Active scanning, penetration testing or intrusive diagnostic activity should not be conducted on operational interlocking equipment without appropriate technical assessment, authorisation and safeguards.
8. Protecting ETCS Trackside and Onboard Equipment
ETCS cybersecurity requires a coordinated approach to trackside and onboard subsystems. Both environments must be considered, including their communication interfaces and maintenance arrangements.
8.1 Trackside Protection
- Identify and document ETCS equipment and communication dependencies.
- Protect RBC and engineering infrastructure through appropriate network segmentation.
- Restrict access to trackside configuration and maintenance interfaces.
- Control software and configuration changes.
- Monitor relevant communication and administrative events.
- Apply supplier-approved security updates and vulnerability mitigations.
- Protect interfaces between interlocking, LEU, RBC and other systems.
8.2 Onboard Protection
- Control physical and logical access to onboard equipment.
- Protect diagnostic and maintenance interfaces.
- Verify the integrity and origin of software updates.
- Manage connections to depot and maintenance networks.
- Control removable media and portable engineering devices.
- Maintain configuration and software version records.
- Coordinate onboard cybersecurity with fleet maintenance procedures.
Onboard systems may have limited connectivity during normal operation. This does not remove the need for cybersecurity controls; it changes how monitoring, updates, evidence collection and maintenance access should be organised.
9. Securing Eurobalises and Trackside Information
Eurobalises provide intermittent information transfer from trackside to train. Fixed or switchable balises store data such as position references, gradients and speed-related information.
Because a Eurobalise is a passive device, its security cannot be assessed in the same way as a conventional IP-connected network device.
The wider information chain should be considered, including:
- Authoring and validation of balise telegram data.
- Configuration of switchable balises and associated LEUs.
- Protection of engineering and programming tools.
- Control of maintenance and replacement activities.
- Verification of approved configuration baselines.
- Physical protection of relevant trackside equipment.
Security controls should be based on the actual balise technology, its interfaces and the processes used to create and maintain the information it transmits.
10. Railway Radio Communication and ETCS Security
Railway radio communication supports operational voice and data services. In ETCS Level 2 environments, radio communication is used for the exchange of information between the train and the Radio Block Centre.
GSM-R is the established railway mobile radio technology in many networks. FRMCS is being developed as its successor, based on newer communication technologies.
Cybersecurity considerations include:
- Protection of network infrastructure and management interfaces.
- Authentication and control of authorised devices and users.
- Availability and resilience of communication services.
- Monitoring of network events and abnormal traffic patterns.
- Secure configuration and lifecycle management.
- Protection of interfaces with ETCS and other railway systems.
- Management of migration and coexistence between communication generations.
Radio security should not be reduced to encryption alone. Availability, network management, equipment configuration, identity, operational procedures and physical infrastructure also contribute to the overall risk.
11. Network Segmentation for Signalling Environments
Network segmentation reduces unnecessary communication between systems and limits the potential movement of an attacker across connected environments.
Railway signalling architectures may use separate security zones for:
- Interlocking and signalling control.
- ETCS trackside equipment.
- RBC infrastructure.
- Engineering and maintenance systems.
- Railway telecommunications.
- Traffic management and control centres.
- Enterprise IT and external supplier access.
Communication between zones should be based on documented operational requirements. Firewalls, controlled gateways and industrial demilitarised zones may be used where appropriate.
IEC 62443 uses the concepts of zones and conduits to support risk-based security architecture. A zone groups assets with common security requirements, while a conduit defines controlled communication between zones.
Segmentation should not be treated as a simple exercise in creating VLANs. It requires asset identification, communication analysis, risk assessment and verification of the implemented controls.
For further information, see Railway Cybersecurity Architecture: IT, OT and Network Segmentation.
12. Monitoring and Detecting Signalling Cyber Threats
Monitoring provides visibility into security-relevant events and can help identify suspicious activity before it develops into a major incident.
Signalling monitoring may include:
- Authentication and privileged access events.
- Engineering workstation activity.
- Configuration and software changes.
- Communication between signalling components.
- Remote maintenance sessions.
- Network devices and security boundary events.
- Changes to approved system baselines.
- Loss of monitoring or logging capability.
Passive network monitoring is often appropriate for sensitive operational environments because it observes traffic without actively interrogating equipment. Active scanning and intrusive testing require careful compatibility assessment and authorisation.
Security monitoring must also account for planned maintenance, commissioning, testing and operational changes. Unusual activity is not necessarily malicious, and alerts need to be interpreted by personnel with appropriate signalling and OT knowledge.
See also Railway Cybersecurity Monitoring and OT Security Operations Centre.
13. Vulnerability Management and Software Updates
Signalling equipment may have long operational lifecycles and depend on specialised software and hardware. Some components may not support conventional patching methods or may require extensive testing before updates can be introduced.
A railway vulnerability management process should include:
- Maintaining an inventory of hardware and software versions.
- Monitoring relevant supplier security advisories.
- Assessing vulnerabilities against actual system exposure and architecture.
- Evaluating operational and safety implications of proposed changes.
- Testing updates in a suitable controlled environment.
- Obtaining required approvals before deployment.
- Maintaining rollback and recovery arrangements.
- Documenting accepted risks and compensating controls.
Where immediate patching is not feasible, alternative controls may include network isolation, restricted access, additional monitoring and removal of unnecessary services. Such measures should be documented and reviewed rather than treated as permanent substitutes for lifecycle management.
14. Remote Maintenance and Supplier Access
Signalling systems are often supported by manufacturers, system integrators and specialist maintenance organisations. Remote access can reduce maintenance time and support troubleshooting, but it can also create an attack path into sensitive environments.
Recommended controls include:
- Individual accounts for each authorised person.
- Multi-factor authentication where technically supported.
- Time-limited access approved by the system owner.
- Access restricted to the required systems and functions.
- Controlled jump servers or secure access gateways.
- Monitoring and recording of relevant sessions.
- Removal of access when contracts or tasks end.
- Security requirements for subcontractors and supplier devices.
VPN connectivity alone does not provide complete security. Access permissions, endpoint security, session monitoring and network restrictions remain necessary.
For additional guidance, see Railway Remote Access Security: Securing Remote Maintenance and Third-Party Connections.
15. Cybersecurity and Functional Safety: Two Different Disciplines
Railway signalling systems are designed and assessed according to functional safety principles. Cybersecurity introduces additional considerations because malicious or accidental digital activity may affect the assumptions, functions or operating conditions on which safety assurance depends.
However, functional safety and cybersecurity are not interchangeable.
- Functional safety addresses risks arising from failures and hazardous system behaviour.
- Cybersecurity addresses threats that may exploit digital vulnerabilities or compromise systems, information and services.
- Safety Integrity Level (SIL) is a safety-related classification used in relevant railway and industrial safety standards.
- Security Level (SL) is a cybersecurity concept used in the IEC 62443 framework.
SIL and SL are not equivalent and must not be directly compared. A system with a high SIL does not automatically have a high cybersecurity level.
Cybersecurity risk assessment should identify whether a threat could affect safety-related functions, system assumptions or operational procedures. Where such an interface exists, security and safety specialists should coordinate their assessments.
CLC/TS 50701:2023 provides railway-specific cybersecurity guidance in the context of the RAMS lifecycle. It addresses cybersecurity requirements and activities arising from threats and vulnerabilities; it does not replace functional safety requirements.
16. Testing and Assurance of Signalling Cybersecurity
Security assurance provides evidence that the required cybersecurity measures have been appropriately designed, implemented and maintained.
Testing activities should be selected according to system criticality, architecture, operational constraints and supplier requirements.
| Assurance activity | Purpose | Important consideration |
|---|---|---|
| Architecture review | Identify interfaces, trust boundaries and potential attack paths | Use accurate system documentation |
| Configuration review | Check security settings and approved baselines | Use vendor-approved procedures |
| Vulnerability assessment | Identify known weaknesses and exposure | Assess compatibility before scanning operational equipment |
| Penetration testing | Evaluate selected security controls under controlled conditions | Define scope, approvals and safety safeguards |
| Software integrity verification | Check the origin and integrity of software and updates | Use trusted validation mechanisms |
| Access control testing | Verify account permissions and authentication arrangements | Include supplier and maintenance access |
| Recovery testing | Assess restoration of approved configurations and services | Coordinate with operational and safety procedures |
Testing should not introduce unacceptable risks to live signalling systems. Where possible, intrusive testing should be conducted in representative test environments, laboratories or controlled commissioning conditions.
17. Incident Response for Signalling Cybersecurity
When a potential cyber incident affects signalling infrastructure, the response must be coordinated between cybersecurity specialists, signalling engineers, system owners and railway operations personnel.
A suitable response framework should include:
- Detection and validation: Determine whether the event is a genuine security concern or an authorised operational activity.
- Operational assessment: Identify the systems involved and evaluate potential effects on railway services.
- Escalation: Notify the authorised technical and operational decision-makers.
- Controlled containment: Apply approved measures without creating additional operational or safety risks.
- Investigation: Preserve relevant logs, configurations and technical evidence.
- Recovery: Restore systems using approved configurations and validated procedures.
- Review: Identify lessons, update risk assessments and improve controls.
Automatic disconnection or shutdown should not be treated as a universal response. The appropriate action depends on the system, operational state, safety implications and approved procedures.
For the complete incident management lifecycle, see Railway Cybersecurity Incident Response and Resilience.
18. Standards and Regulatory Framework
Railway signalling cybersecurity is influenced by railway-specific technical specifications, industrial cybersecurity standards, safety lifecycle standards and applicable cybersecurity legislation.
18.1 CLC/TS 50701:2023 – Railway Applications: Cybersecurity
CLC/TS 50701:2023 provides railway-specific guidance and specifications for managing cybersecurity in the context of the EN 50126 RAMS lifecycle.
It applies to communications, signalling and processing, rolling stock and fixed installations. It supports the identification, assessment, treatment and ongoing management of cybersecurity risks throughout the system lifecycle.
It is a technical specification, not a law, automatic certification or replacement for functional safety standards.
18.2 IEC 62443 Series
The IEC 62443 series provides security requirements and guidance for industrial automation and control systems. Relevant parts include:
- IEC 62443-2-1: Security programme requirements for asset owners.
- IEC 62443-2-4: Security programme requirements for industrial automation and control system service providers.
- IEC 62443-3-2: Security risk assessment and system design using zones and conduits.
- IEC 62443-3-3: System security requirements and security levels.
- IEC 62443-4-1: Secure product development lifecycle requirements.
- IEC 62443-4-2: Technical security requirements for industrial automation and control system components.
18.3 Railway RAMS and Signalling Standards
Cybersecurity assurance should be coordinated with the applicable railway safety and lifecycle framework. Relevant standards include:
- EN 50126: Railway RAMS – Reliability, Availability, Maintainability and Safety lifecycle processes.
- EN 50129: Safety-related electronic systems for signalling.
- EN 50716:2023: Requirements for software development for railway control and protection systems.
- EN 50159: Safety-related communication in transmission systems.
These standards address different aspects of railway engineering and safety. They should not be presented as cybersecurity standards in themselves.
18.4 European Cybersecurity Requirements
The NIS2 Directive (EU) 2022/2555 establishes cybersecurity risk management and incident reporting requirements for entities within its scope. Rail transport is included in the high-criticality sectors, but specific obligations depend on entity classification, national implementation and applicable scope provisions.
The Critical Entities Resilience Directive (EU) 2022/2557 addresses broader resilience against a range of threats. It complements cybersecurity measures through an all-hazards approach.
18.5 Türkiye
Türkiye’s Law No. 7545 on Cybersecurity, adopted in March 2025, provides a national framework for cybersecurity governance and responsibilities. Railway organisations should assess their obligations in line with the applicable secondary legislation, competent authority decisions and sector-specific requirements.
The inclusion of transport within national critical infrastructure cybersecurity governance does not by itself mean that every railway system or facility has been individually designated as a critical entity.
19. Practical Cybersecurity Roadmap for Railway Signalling
Railway organisations can develop signalling cybersecurity capabilities through a phased programme.
Phase 1: Asset and Architecture Identification
- Inventory signalling assets and system owners.
- Document trackside and onboard architecture.
- Identify interlocking, ETCS, communication and maintenance interfaces.
- Record software, firmware and configuration baselines.
- Identify suppliers and external access paths.
Phase 2: Risk Assessment
- Define system boundaries and operational requirements.
- Identify credible threat scenarios.
- Assess vulnerabilities and existing controls.
- Evaluate operational and safety-related consequences.
- Document risk owners and residual risks.
Phase 3: Security Architecture and Access Control
- Define appropriate security zones and conduits.
- Restrict engineering and maintenance access.
- Implement controlled remote access arrangements.
- Protect configuration and software update processes.
- Review interfaces with corporate IT and supplier environments.
Phase 4: Monitoring and Assurance
- Introduce suitable passive monitoring where appropriate.
- Collect relevant security and administrative logs.
- Establish detection and escalation procedures.
- Test selected controls in controlled environments.
- Review supplier security and vulnerability management.
Phase 5: Lifecycle Improvement
- Reassess risks after system modifications.
- Review unsupported equipment and legacy components.
- Conduct security and recovery exercises.
- Update procedures and personnel training.
- Maintain evidence of security assurance and residual risk acceptance.
20. Frequently Asked Questions
What is railway signalling cybersecurity?
It is the protection of railway signalling and train control systems against cyber threats, unauthorised access, manipulation and disruption. It covers equipment such as interlocking, ETCS, RBCs, communication networks and engineering systems.
Is ETCS the same as ERTMS?
No. ETCS is the European Train Control System and forms part of the broader ERTMS framework. ERTMS also includes railway mobile radio and associated operational arrangements.
Is interlocking part of ERTMS?
Interlocking is not an ERTMS component, but it plays an essential role in many ERTMS architectures and exchanges information with ETCS trackside equipment.
Can Eurobalises be hacked like network devices?
Eurobalises are passive devices and should not be treated as conventional IP network nodes. Their security assessment should consider the complete information chain, including telegram generation, configuration, LEU interfaces, maintenance tools and physical access.
Does ETCS Level 2 create additional cybersecurity risks?
ETCS Level 2 introduces continuous radio communication between trains and trackside infrastructure through a Radio Block Centre. This creates communication and infrastructure dependencies that must be included in the cybersecurity assessment. It does not mean that every Level 2 implementation has the same vulnerabilities.
Does a high SIL guarantee cybersecurity?
No. Safety Integrity Level and Security Level address different disciplines. A high SIL does not automatically indicate strong cybersecurity protection.
Can signalling systems be penetration tested?
Yes, but testing must be carefully scoped, authorised and planned. Intrusive testing of live operational equipment may introduce unacceptable risks and should not be conducted without appropriate assessment and safeguards.
Who is responsible for signalling cybersecurity?
Responsibility is shared across infrastructure managers, railway undertakings, system integrators, manufacturers and maintenance providers according to their roles and contractual or regulatory obligations. The system owner and relevant risk owners must be clearly identified.
21. Conclusion
Railway signalling cybersecurity is a specialised discipline that requires a detailed understanding of signalling architecture, train control functions, communication systems and operational constraints. Interlocking, ETCS, RBCs, Eurobalises, onboard equipment and engineering environments must be assessed as interconnected elements rather than isolated devices.
Effective protection depends on accurate asset inventories, risk-based security architecture, controlled maintenance access, software and configuration integrity, monitoring, vulnerability management and coordinated incident response.
Most importantly, cybersecurity must be integrated with railway safety and lifecycle engineering without confusing the objectives of the two disciplines. Safety assurance does not replace cybersecurity, and cybersecurity controls must not undermine the safe operation of railway systems.
As railway networks move towards greater digitalisation, automation and advanced communication technologies, signalling cybersecurity will remain a central requirement for reliable, interoperable and resilient railway operations.
References and Further Reading
- European Commission, What is ERTMS and How Does It Work? European Commission.
- European Commission, Subsystems and Constituents of the ERTMS. European Commission.
- European Union Agency for Railways (ERA), ERTMS – Frequently Asked Questions. ERA.
- European Union Agency for Cybersecurity (ENISA), Railway Cybersecurity, 2020. ENISA publication.
- European Union Agency for Cybersecurity (ENISA), Railway Cybersecurity: Good Practices in Cyber Risk Management, 2021. ENISA publication.
- ENISA and European Rail ISAC, Zoning and Conduits for Railways, 2022. ENISA overview.
- CENELEC, CLC/TS 50701:2023 – Railway Applications: Cybersecurity. BSI publication information.
- International Electrotechnical Commission, IEC 62443 Series – Security for Industrial Automation and Control Systems. IEC.
- European Commission, Control-Command and Signalling Technical Specifications for Interoperability. European Commission.